• CSCD核心库收录期刊
  • 中文核心期刊
  • 中国科技核心期刊

ELECTRIC POWER CONSTRUCTION ›› 2022, Vol. 43 ›› Issue (4): 140-148.doi: 10.12204/j.issn.1000-7229.2022.04.015

• Power Economic Research • Previous Articles    

Energy Flow Analysis Method and Energy Efficiency Evaluation of Integrated Energy Service Station System

LI Yan1(), XI Wenqing2(), LIU Ziyan2(), MA Chen2(), ZHANG Qun1(), WANG Qiu1(), WANG Qingshan1(), LIANG Haifeng2()   

  1. 1. Economic and Technological Research Institute, State Grid Jiangsu Electric Power Co., Ltd., Nanjing 210008, China
    2. School of Electrical and Electronic Engineering, North China Electric Power University, Baoding 071003, Hebei Province, China
  • Received:2021-07-08 Online:2022-04-01 Published:2022-03-24
  • Contact: LIANG Haifeng E-mail:21030074@qq.com;1015159382@qq.com;liuziyan131@163.com;354924850@qq.com;527610706@qq.com;2034259649@qq.com;948812737@qq.com;hfliang@ncepu.edu.cn
  • Supported by:
    State Grid Jiangsu Electric Power Company Science and Technology Project Funding(SGTYHT/19-JS-215)

Abstract:

Improving energy utilization efficiency is one of the main goals of the construction of integrated energy service stations. In order to reflect the characteristics of energy utilization, conversion and loss of integrated energy service stations, this paper firstly considers three aspects of macro-energy efficiency micro-energy efficiency and energy economy. Six evaluation indices for energy utilization, renewable energy utilization, EV charging station energy efficiency, data center energy efficiency, energy economic cost, and economic development adaptability are proposed, and an energy efficiency evaluation index system for integrated energy service stations is established. Secondly, the weighted directed graph is used to simulate the internal energy flow of the integrated energy service station, and the calculation method of the system energy flow and the energy efficiency evaluation method are proposed. Finally, this paper takes an integrated energy service station as an example, an evaluation scenario of integrated energy service station is established, and the proposed method is applied to conduct a comprehensive energy efficiency evaluation of the system. The results show that the model and evaluation method proposed in this paper can reflect the energy utilization in the system, is suitable for the pre-evaluation of system energy efficiency, and has reference significance for the planning and operation of the integrated energy service station.

Key words: energy integrated service station, index system, directed graph, energy efficiency evaluation

CLC Number: