基于TF-PARNet的有源配电网轻量化故障诊断

作者信息 +

A Lightweight Fault Diagnosis Method for TF-PARNet-Based Active Distribution Networks

Author information +
文章历史 +

摘要

【目的】针对有源配电网并网点故障信号非平稳特征提取困难,以及现有深度学习模型参数冗余难以满足边缘智能终端实时部署需求的难题,提出一种基于轻量化时频双分支金字塔注意力网络(time-frequency dual-branch pyramid attention residual network, TF-PARNet)的故障诊断方法。【方法】首先,构建时域与频域双分支并行架构,并引入差异化多头自注意力机制,分别捕获暂态波形突变与全局频谱依赖;其次,设计基于门控机制的智能自适应融合模块,实现异构时频特征的动态加权与重标定;最后,利用深度可分离卷积重构金字塔残差单元,解耦空间与通道相关性以实现模型极致压缩。【结果】在PSCAD/EMTDC平台上搭建IEEE 13节点系统进行仿真。测试结果表明,在叠加高斯噪声与时序偏移的复杂工况下,TF-PARNet 的平均准确率达96.14%,模型参数量仅为151.0 ×103个,在纯CPU环境下的单样本推理时间低至3.8 ms。【结论】该方法在保证高保真特征解析的同时大幅削减了计算开销,兼具故障辨识的高准确性与边缘计算的高效性,为资源受限的配电网就地化智能保护提供了可靠的工程方案。

Abstract

[Objective] To address the challenges of extracting non-stationary features from fault signals at the Point of Common Coupling in active distribution networks, and to overcome the redundancy of existing deep learning models that hinders real-time deployment on edge intelligent terminals, a fault diagnosis method based on a lightweight time-frequency dual-branch pyramid attention residual network (TF-PARNet) is proposed. [Methods] First, a time-frequency dual-branch parallel architecture was constructed, incorporating a differentiated multi-head self-attention mechanism to capture transient waveform mutations and global spectral dependencies, respectively. Second, an intelligent adaptive fusion module based on a gating mechanism was designed to achieve dynamic weighting and recalibration of heterogeneous time-frequency features. Finally, the pyramid residual unit was reconstructed using depthwise separable convolutions to decouple spatial and channel correlations, achieving extreme model compression. [Results] Simulations were conducted on an IEEE 13-node system using the PSCAD/EMTDC platform. The test results demonstrate that under complex working conditions with superimposed Gaussian noise and temporal offsets, TF-PARNet achieves a mean accuracy of 96.14%. The model contains only 151.0 × 103 parameters, and the single-sample inference time in a pure CPU environment is as low as 3.8 ms. [Conclusion] The proposed method reduces computational overhead while ensuring high-fidelity feature analysis. It combines high diagnostic accuracy with edge computing efficiency, providing a reliable engineering solution for the localized intelligent protection of resource-constrained distribution networks.

关键词

有源配电网 / 故障诊断 / 时频分析 / 自适应融合 / 轻量化网络

Key words

active distribution network / fault diagnosis / time-frequency analysis / adaptive fusion / lightweight network

引用本文

导出引用
储云迪, 贺梦洁, 侯世玺, 等. 基于TF-PARNet的有源配电网轻量化故障诊断[J]. 电力建设. 2026, 47(11): 75-88 https://doi.org/10.12204/j.issn.1000-7229.2026.11.006
CHU Yundi, HE Mengjie, HOU Shixi, et al. A Lightweight Fault Diagnosis Method for TF-PARNet-Based Active Distribution Networks[J]. Electric Power Construction. 2026, 47(11): 75-88 https://doi.org/10.12204/j.issn.1000-7229.2026.11.006
中图分类号: TM732   

参考文献

[1]
侯思祖, 金雅慧. 基于谐波特性与ConvNeXt网络的配电网故障区段定位方法[J]. 供用电, 2025, 42(11): 67-76.
Hou Sizu, Jin Yahui. Research on fault section location of distribution network based on harmonic characteristics and ConvNeXt network[J]. Distribution & Utilization, 2025, 42(11): 67-76.
[2]
何小龙, 高红均, 王仁浚, 等. 基于图深度强化学习的有源配电网故障恢复方法[J]. 电网技术, 2025, 49(10): 4342-4352.
He Xiaolong, Gao Hongjun, Wang Renjun, et al. Fault recovery method of active distribution network based on graph deep reinforcement learning[J]. Power System Technology, 2025, 49(10): 4342-4352.
[3]
陈继明, 陈文淙, 仉志华, 等. 基于波形相似性的柔性互联配电网短路故障区段定位方法[J]. 电力工程技术, 2025, 44(1): 104-114.
Chen Jiming, Chen Wencong, Zhang Zhihua, et al. Short-circuit fault location method of flexible interconnected distribution network based on waveform similarity[J]. Electric Power Engineering Technology, 2025, 44(1): 104-114.
[4]
林湘宁, 刘胜福, 翁汉琍, 等. 可实现故障快速响应和全面覆盖的有源高压配电网单端暂态量阶段式保护方案[J]. 广东电力, 2024, 37(10): 121-134.
Lin Xiangning, Liu Shengfu, Weng Hanli, et al. Active high voltage distribution network single-ended transient stage protection scheme for fast fault response and comprehensive coverage[J]. Guangdong Electric Power, 2024, 37(10): 121-134.
[5]
徐小健, 于飞. 基于输出电压轨迹的三相逆变器开关管开路故障诊断[J]. 中国电机工程学报, 2024, 44(3): 1106-1116.
Xu Xiaojian, Yu Fei. A fault diagnosis method based on output voltage patterns for switch open-circuit fault of three-phase inverters[J]. Proceedings of the CSEE, 2024, 44(3): 1106-1116.
[6]
Ganivada P K, Jena P. A fault location identification technique for active distribution system[J]. IEEE Transactions on Industrial Informatics, 2022, 18(5): 3000-3010.
[7]
齐郑, 黄朝晖, 陈艳波. 基于零序分量的阻抗法配电网故障定位技术[J]. 电力系统保护与控制, 2023, 51(6): 54-62.
Qi Zheng, Huang Zhaohui, Chen Yanbo. Impedance fault location technology for a distribution network based on a zero-sequence component[J]. Power System Protection and Control, 2023, 51(6): 54-62.
[8]
Baharozu E, Ilhan S, Soykan G. A data-driven-based high impedance fault location method considering traveling waves in branched distribution networks[J]. IEEE Access, 2024, 12: 186535-186546.
[9]
付华, 王婧羽. 基于SR-VMD的微弱故障行波检测方法[J]. 电力系统保护与控制, 2021, 49(1): 156-162.
Fu Hua, Wang Jingyu. Weak fault traveling wave detection method based on SR-VMD[J]. Power System Protection and Control, 2021, 49(1): 156-162.
[10]
Lan S, Chen M J, Chen D Y. A novel HVDC double-terminal non-synchronous fault location method based on convolutional neural network[J]. IEEE Transactions on Power Delivery, 2019, 34(3): 848-857.
[11]
吴佳享, 孙云莲, 陈楚昭. 基于MRSVD-VMD的多分支配电网故障定位[J]. 电力系统及其自动化学报, 2022, 34(11): 58-65.
Wu Jiaxiang, Sun Yunlian, Chen Chuzhao. Fault location of multi-branch distribution network based on MRSVD-VMD[J]. Proceedings of the CSU-EPSA, 2022, 34(11): 58-65.
[12]
张广斌, 陈柏宇, 束洪春, 等. 基于时域波形特征认知的输电线路近端故障辨识与定位[J]. 电力系统自动化, 2024, 48(5): 146-156.
Zhang Guangbin, Chen Boyu, Shu Hongchun, et al. Identification and location of near-end faults in transmission lines based on time-domain waveform characteristic recognition[J]. Automation of Electric Power Systems, 2024, 48(5): 146-156.
[13]
周军, 曲振国, 战紫昂. 基于CPO-VMD的输电线路行波故障测距方法[J]. 电力科学与技术学报, 2025, 40(2): 30-41.
Zhou Jun, Qu Zhenguo, Zhan Ziang. Traveling wave fault location method of transmission line based on CPO-VMD[J]. Journal of Electric Power Science and Technology, 2025, 40(2): 30-41.
[14]
张帝, 宋兴荣, 唐海国, 等. 基于自适应VMD和WVD的配电网故障行波检测方法[J]. 电力科学与技术学报, 2024, 39(2): 80-90.
Zhang Di, Song Xingrong, Tang Haiguo, et al. Fault traveling wave detection method of distribution network based on adaptive VMD and WVD[J]. Journal of Electric Power Science and Technology, 2024, 39(2): 80-90.
[15]
张大海, 张晓炜, 孙浩, 等. 基于卷积神经网络的交直流输电系统故障诊断[J]. 电力系统自动化, 2022, 46(5): 132-140.
Zhang Dahai, Zhang Xiaowei, Sun Hao, et al. Fault diagnosis for AC/DC transmission system based on convolutional neural network[J]. Automation of Electric Power Systems, 2022, 46(5): 132-140.
[16]
Muthamizhan T, Aijaz M, Sekhar D C, et al. Wavelet-ANN based detection of fault location of hybrid renewable energy sources connected power transmission system[J]. International Journal of Renewable Energy Research (IJRER), 2024, 14(3): 551-562.
[17]
翁楦乔, 文成林. 基于深度特征聚类和RNN的电网故障诊断[J]. 控制工程, 2022, 29(1): 175-181.
Weng Xuanqiao, Wen Chenglin. Fault diagnosis of power grid based on deep feature clustering and recurrent neural network[J]. Control Engineering of China, 2022, 29(1): 175-181.
[18]
胡登宇, 王宝华, 刘晋宏. 基于改进图神经网络的含源配电网故障诊断方法及效果[J]. 科学技术与工程, 2025, 25(21): 8936-8944.
Hu Dengyu, Wang Baohua, Liu Jinhong. Fault diagnosis in distribution networks with distributed generation based on improved graph neural network[J]. Science Technology and Engineering, 2025, 25(21): 8936-8944.
[19]
胡国栋, 马宏忠, 孙维, 等. 融合双向时序特征与多头注意力机制的电缆故障定位方法[J]. 广东电力, 2025, 38(12): 33-43.
Hu Guodong, Ma Hongzhong, Sun Wei, et al. Cable fault localization method integrating bidirectional temporal features and multi-head attention mechanism[J]. Guangdong Electric Power, 2025, 38(12): 33-43.
[20]
Wang Y P, Liu F, Zeng X J, et al. A novel traveling wave signal detection method based on inverse system inversion[J]. Electric Power Systems Research, 2025, 248: 111917.
[21]
王有鹏, 曾祥君, 刘丰, 等. 基于行波全频带特征的配电网故障行波波头标定方法[J]. 电力系统保护与控制, 2025, 53(1): 171-180.
Wang Youpeng, Zeng Xiangjun, Liu Feng, et al. Fault traveling wave head calibration method for a distribution network based on the full band characteristics of a traveling wave[J]. Power System Protection and Control, 2025, 53(1): 171-180.
[22]
Liu F, Xie L W, Yu K, et al. A novel fault location method based on traveling wave for multi-branch distribution network[J]. Electric Power Systems Research, 2023, 224: 109753.
[23]
石昱烜, 席燕辉, 张伟杰. 基于GAF-ResNet50的配电网故障区段定位[J]. 电力科学与技术学报, 2025, 40(2): 122-130, 149.
Shi Yuxuan, Xi Yanhui, Zhang Weijie. Distribution network fault segment location based on GAF-ResNet50[J]. Journal of Electric Power Science and Technology, 2025, 40(2): 122-130, 149.
[24]
叶远波, 王吉文, 邵庆祝, 等. 配电网故障识别Transformer-联邦迁移学习算法设计[J]. 电力系统及其自动化学报, 2025, 37(10): 120-128.
Ye Yuanbo, Wang Jiwen, Shao Qingzhu, et al. Design of transformer-based federated transfer learning algorithm for distribution network fault recognition[J]. Proceedings of the CSU-EPSA, 2025, 37(10): 120-128.
[25]
张彼德, 邱杰, 娄广鑫, 等. 基于CNN和Transformer的轻量化电能质量扰动识别模型[J]. 电力工程技术, 2025, 44(1): 69-78.
Zhang Bide, Qiu Jie, Lou Guangxin, et al. A lightweight power quality disturbance recognition model based on CNN and Transformer[J]. Electric Power Engineering Technology, 2025, 44(1): 69-78.
[26]
秦苏亚, 薛永端, 刘砾钲, 等. 有源配电网小电流接地故障暂态特征及其影响分析[J]. 电工技术学报, 2022, 37(3): 655-666.
Qin Suya, Xue Yongduan, Liu Lizheng, et al. Transient characteristics and influence of small current grounding faults in active distribution network[J]. Transactions of China Electrotechnical Society, 2022, 37(3): 655-666.
[27]
王宾, 崔鑫, 董新洲. 配电线路弧光高阻故障检测技术综述[J]. 中国电机工程学报, 2020, 40(1): 96-107, 377.
Wang Bin, Cui Xin, Dong Xinzhou. Overview of arc high impedance grounding fault detection technologies in distribution system[J]. Proceedings of the CSEE, 2020, 40(1): 96-107, 377.
[28]
黄昕飞, 王有鹏, 刘凤, 等. 利用行波主频分量幅值信息的多分支配电网故障定位方法[J]. 电力系统及其自动化学报, 2025, 37(12): 15-23.
Huang Xinfei, Wang Youpeng, Liu Feng, et al. Fault location method for multi-branch distribution network using amplitude information of traveling wave dominant frequency components[J]. Proceedings of the CSU-EPSA, 2025, 37(12): 15-23.
[29]
张小凤, 李昂, 周雷金, 等. 基于AIBPSO算法的含DG主动配电网分区故障定位[J]. 供用电, 2024, 41(12): 93-101.
Zhang Xiaofeng, Li Ang, Zhou Leijin, et al. Partition fault location of active distribution network with DG based on AIBPSO algorithm[J]. Distribution & Utilization, 2024, 41(12): 93-101.
[30]
余波, 高学军, 王灿, 等. 基于行波特征与KOA-CNN-BiGRU-AM的柔直输电线路故障诊断[J]. 电力工程技术, 2025, 44(2): 185-196.
Yu Bo, Gao Xuejun, Wang Can, et al. Fault diagnosis of MMC-MTDC based on traveling wave characteristics and KOA-CNN-BiGRU-AM[J]. Electric Power Engineering Technology, 2025, 44(2): 185-196.
[31]
孟宏宇, 张建良, 蔡兆龙, 等. 基于CNN-BiLSTM-Attention的直流微电网故障诊断研究[J]. 中国电机工程学报, 2025, 45(4): 1369-1380.
Meng Hongyu, Zhang Jianliang, Cai Zhaolong, et al. Research on DC microgrid fault diagnosis based on CNN-BiLSTM-attention[J]. Proceedings of the CSEE, 2025, 45(4): 1369-1380.
[32]
白星振, 宋昭杉, 葛磊蛟, 等. 含分布式电源的复杂配电网相间故障定位等效解耦模型[J]. 电力建设, 2022, 43(2): 45-53.
摘要
分布式电源规模化接入,使配电网拓扑结构和组成元素越来越复杂,传统矩阵算法由于馈线开关处故障电流方向难以确定已不再适用于配电网相间故障定位。为有效将复杂配电网的拓扑结构简化,基于深度优先原则对配电网进行解耦,使其变成由若干个树干状结构组成的网络;针对复杂配电网故障定位矩阵算法计算量大、步骤复杂的难题,提出了一种新的复杂配电网故障定位矩阵算法,与传统矩阵算法相比,该方法对配电网T型区段及末梢区段故障的定位更加精确。最后,通过典型园区配电网模型与改进的 IEEE 33系统案例,验证了所提方法既能实现配电网的故障定位,又能简化复杂配电网结构,与以往的行波法相比,文章提出的方法缩短了定位时间,具有较好的工程应用价值。
Bai Xingzhen, Song Zhaoshan, Ge Leijiao, et al. An equivalent decoupling model for fault location in complex distribution network with distributed generation[J]. Electric Power Construction, 2022, 43(2): 45-53.

Since distributed power supply is connected to distribution networks on a large scale, its topology and components are becoming more and more complex. As the direction of fault current at feeder switches is difficult to determine, a new matrix algorithm for equivalent decoupling fault location in complex distribution networks is proposed in this paper. In order to simplify the topology of complex distribution network effectively, the distribution network is decoupled according to the principle of depth priority to make it a network composed of tree trunks. A new fault-location matrix algorithm for complex distribution network is presented to solve the problem of large computation and complex steps in fault-location matrix algorithm for complex distribution network. Compared with traditional matrix algorithm, this method is more accurate for T-section and terminal section of power network fault location. Finally, through the typical park distribution network model and the improved IEEE 33-node system case, the method proposed in this paper can not only locate the faults in the distribution network, but also simplify the complex distribution network structure. Compared with the traveling wave method, the proposed method shortens the locating time and has better application value.

[33]
周军, 曲振国, 战紫昂. 融合小波去噪与VMD-NTEO的输电线路故障定位[J]. 电力系统及其自动化学报, 2025, 37(7): 141-150.
Zhou Jun, Qu Zhenguo, Zhan Ziang. Transmission line fault location based on fusion of wavelet denoising and VMD-NTEO[J]. Proceedings of the CSU-EPSA, 2025, 37(7): 141-150.
[34]
Howard A G, Zhu M L, Chen B, et al. MobileNets: efficient convolutional neural networks for mobile vision applications[PP/OL]. arXiv (2017-04-17)[2026-03-12]. https://doi.org/10.48550/arXiv.1704.04861.
[35]
Li Q Y, Luo H, Cheng H, et al. Incipient fault detection in power distribution system: a time-frequency embedded deep-learning-based approach[J]. IEEE Transactions on Instrumentation and Measurement, 2023, 72: 1-14.
[36]
Ji L P, Tian X L, Wei Z H, et al. Intelligent fault diagnosis in power distribution networks using LSTM-DenseNet network[J]. Electric Power Systems Research, 2025, 239: 111202.
[37]
Aucoin B M, Jones R H. High impedance fault detection implementation issues[J]. IEEE Transactions on Power Delivery, 1996, 11(1): 139-148.
[38]
Yang D, Lu B P, Lu H W. High-resistance grounding fault detection and line selection in resonant grounding distribution network[J]. Electronics, 2023, 12(19): 4066.
[39]
Chen Y Z, Gao Y F, Chen X C, et al. A novel strategy for fault location, isolation, and service restoration in active distribution networks[J]. Measurement Science and Technology, 2025, 36(6): 066201.
When a fault arises in an active distribution network, both the grid upstream of the fault point and the distributed generation (DG) downstream of the fault point contribute short-circuit currents, posing challenges for existing centralized feeder automation (FA) technologies in accurately locating and isolating the fault. Moreover, the radial network structure of the distribution network can lead to power outages for downstream loads when the DG downstream of the fault point ceases operation due to islanding effects. To tackle this issue, this paper introduces a communication-based distributed FA strategy that employs interlocking signals between adjacent switches to pinpoint and isolate faults in active distribution networks, effectively minimizing the scope of fault-induced power outages. Furthermore, to guarantee uninterrupted power supply to the non-fault zones located downstream of the fault point, an inverter control strategy integrating voltage negative feedback control, reactive power negative feedback control, and quasi-synchronization grid-connection control is proposed. This strategy allows for seamless switching between grid-following and grid-forming inverter control modes, enabling adaptive grid-connection/islanding control of DGs. Consequently, non-fault areas downstream of the fault point maintain uninterrupted power supply, significantly enhancing the reliability of power supply in distribution networks. Simulation models have been constructed using MATLAB/Simulink to validate the efficacy of the proposed approach.
[40]
舒佳蕾, 陈依林, 曹虹, 等. 基于图注意力网络的配电网故障行波定位方法[J]. 电力科学与技术学报, 2025, 40(1): 85-91.
Shu Jialei, Chen Yilin, Cao Hong, et al. A fault traveling wave localization method for distribution networks based on graph attention networks[J]. Journal of Electric Power Science and Technology, 2025, 40(1): 85-91.
[41]
Sandler M, Howard A, Zhu M L, et al. MobileNetV2: inverted residuals and linear bottlenecks[C]// 2018 IEEE/CVF Conference on Computer Vision and Pattern Recognition. IEEE, 2018: 4510-4520.
[42]
Ab Wahab M N, Nazir A, Zhen Ren A T, et al. Efficientnet-lite and hybrid CNN-KNN implementation for facial expression recognition on raspberry pi[J]. IEEE Access, 2021, 9: 134065-134080.
[43]
Li Z, Ren A, Li J, et al. DSCNN: hardware-oriented optimization for stochastic computing based deep convolutional neural networks[C]// 2016 IEEE 34th International Conference on Computer Design (ICCD). IEEE, 2016: 678-681.
[44]
Hewage P, Behera A, Trovati M, et al. Temporal convolutional neural (TCN) network for an effective weather forecasting using time-series data from the local weather station[J]. Soft Computing, 2020, 24(21): 16453-16482.
Non-predictive or inaccurate weather forecasting can severely impact the community of users such as farmers. Numerical weather prediction models run in major weather forecasting centers with several supercomputers to solve simultaneous complex nonlinear mathematical equations. Such models provide the medium-range weather forecasts, i.e., every 6 h up to 18 h with grid length of 10–20 km. However, farmers often depend on more detailed short-to medium-range forecasts with higher-resolution regional forecasting models. Therefore, this research aims to address this by developing and evaluating a lightweight and novel weather forecasting system, which consists of one or more local weather stations and state-of-the-art machine learning techniques for weather forecasting using time-series data from these weather stations. To this end, the system explores the state-of-the-art temporal convolutional network (TCN) and long short-term memory (LSTM) networks. Our experimental results show that the proposed model using TCN produces better forecasting compared to the LSTM and other classic machine learning approaches. The proposed model can be used as an efficient localized weather forecasting tool for the community of users, and it could be run on a stand-alone personal computer.
[45]
Wang X Y, Zhou Z, Yuan Z H, et al. FD-CNN: a frequency-domain FPGA acceleration scheme for CNN-based image-processing applications[J]. ACM Transactions on Embedded Computing Systems, 2023, 22(6): 1-30.
[46]
顾衍璋, 阳浩, 雷一勇, 等. 面向轻量级芯片化终端的配电网态势感知增强方法[J/OL]. 电力系统及其自动化学报, 2026-03-06. https://doi.org/10.19635/j.cnki.csu-epsa.001804.
Gu Yanzhang, Yang Hao, Lei Yiyong, et al. Enhanced situational awareness method for distribution network oriented to lightweight chip-level terminals[J/OL]. Proceedings of the CSU-EPSA, 2026-03-06.https://doi.org/10.19635/j.cnki.csu-epsa.001804.
[47]
Siddique M N I, Shafiullah M, Mekhilef S, et al. Fault classification and location of a PMU-equipped active distribution network using deep convolution neural network (CNN)[J]. Electric Power Systems Research, 2024, 229: 110178.
[48]
Wang G, Huang M, Bai H, et al. A current differential protection scheme for distribution networks with inverter-interfaced distributed generators considering delay behaviors of sequence component extractors[J]. Electronics, 2023, 12(23): 4727.
The high-level proliferation of inverter-interfaced distributed generators (IIDGs) in modern distribution networks (DNs) has changed system topologies and fault current signatures, which compromises the protective relays in DNs. Investigating IIDG fault behaviors-based protection scheme will benefit the grid’s safety and stability. This paper proposes a novel current differential protection (CDP) scheme that considers the delay behaviors of positive- and negative-sequence component extractors for IIDGs in DNs. A frequency-domain analytical model of the fault current for a grid-connected IIDG with the PQ control strategy and a low-voltage ride-through (LVRT) capability is investigated. The dynamic behavior of the IIDGs considering the sequence-component extractor based on the Pade approximation is presented, where the T/4 delay extractor of the IIDGs causes a two-stage behavior in the fault transient process. It is found that a 5 ms error between the measured and actual values after the fault will affect the transient characteristics of the IIDGs. The transient current generated by the IIDGs during grid faults contains a large number of low-order harmonic components within the range of 0–200 Hz, which is significantly different to the current provided by the power grid. Therefore, the proposed CDP scheme uses protective relays at both terminals to obtain the required transient electric quantity using the Prony method. By constructing the frequency-characteristics ratio (FCR) and the exchanging FCR between two terminal relays, the developed protection criteria are implemented. The accuracy of the fault analysis method, whose maximum computational error is below 0.1%, and the feasibility of the proposed protection scheme are demonstrated by using a 10 kV DN in a PSCAD/EMTDC simulation, which can be applied to various fault conditions and traditional DNs without IIDGs.
[49]
Liu J H, Huang Y T, Chen K, et al. Graph neural networks for fault diagnosis in photovoltaic-integrated distribution networks with weak features[J]. Sensors, 2025, 25(18): 5691.
Effective diagnosis of distribution network faults is crucial to ensuring the reliability of power systems. However, the bidirectional power flow caused by the integration of new energy limits the effectiveness of traditional detection methods. Although data-driven approaches are not restricted by power flow direction, their performance is heavily dependent on the quantity and quality of training samples. In addition, factors such as measurement noise, variable fault impedance, and volatile photovoltaic output complicate fault information. To address this, we present a new fault diagnosis model named the dynamic, adaptive, and coupled dual-field-encoding graph neural network (DACDFE-GNN), which introduces a dynamic aggregation module to assign different weights to reduce noise interference and fully integrates information from observable nodes. On this basis, the coupled dual-field-encoding module is proposed, which encodes topological information and physical–electrical domain information as part of the initial features, thereby capturing fault features and learning the law of feature propagation. The experimental results for the IEEE 34- and IEEE 123-node feeder systems indicate that the proposed model surpasses recent fault diagnosis methods in detection performance, particularly regarding its low training sample rate.

利益冲突声明(Conflict of Interests):

所有作者声明不存在利益冲突。

作者贡献声明(Authors' Contributions):

储云迪负责研究构思与研究指导;贺梦洁负责模型实现、实验验证、数据分析及论文初稿撰写;侯世玺负责研究监督及论文审阅与修订;吕朋蓬、徐挺负责工程场景分析与结果验证;史朋飞负责研究指导及论文审定。所有作者均阅读并同意了论文终稿内容。

基金

国家自然科学基金项目(62476080)
江苏省自然科学基金项目(BK20241779)
云南省重大科技专项计划项目(202402AF080006)

编辑: 张小飞
PDF(4596 KB)

Accesses

Citation

Detail

相关文章
AI小编
你好!我是《电力建设》AI小编,有什么可以帮您的吗?

/

〈 〉