摘要

利用CFD数值模拟Fluent软件,以某600 MW直接空冷机组为例,模拟环境风对空冷凝汽器换热效率的影响,提出在空冷岛周围加装不同形式挡风网的方案。模拟计算结果表明:加装挡风网后,在大风条件下,热风回流和“倒灌”现象均减弱,空冷单元空气流量增加;在环境风速为0~12 m/s的情况下,机组凝汽器平均换热效率可达到72.52%,比不加挡风网时高24.51%。

Abstract

Taking a 600 MW direct air-cooling unit as an example, the influence of environmental wind on the heat transfer efficiency of air-cooled condenser was numerically simulated by using CFD software (Fluent), and the schemes of different windshields installed around the air cooling platform were put forward. The calculation results show that the installation of windshield can reduce the influence of hot air recirculation and the ‘intrusion’ phenomenon, as well increase the air flow in air cooling unit and the average heat transfer of condenser, which can be up to 72.52% and 24.51% higher than that without windshield, under 0 m/s-12 m/s environmental wind speed.

关键词

直接空冷机组 / 凝汽器 / 挡风网 / 数值模拟 / 换热效率

Key words

direct air-cooling unit / condenser / windshield / numerical simulation / heat transfer efficiency

引用本文

导出引用
周兰欣,王晓斐,吴瑞康. 空冷岛加装挡风网对凝汽器换热效率的影响[J]. 电力建设. 2014, 35(1): 88-92 https://doi.org/10.3969/j.issn.1000-7229.2014.01.017
ZHOU Lanxin, WANG Xiaofei, WU Ruikang. Influences of Windshield around Air-Cooled Island on Condenser Heat Transfer Efficiency[J]. Electric Power Construction. 2014, 35(1): 88-92 https://doi.org/10.3969/j.issn.1000-7229.2014.01.017

参考文献

 

[1]丁尔谋.发电厂空冷技术[M].北京:水利电力出版社,1992.
[2]Bari E,Noel J Y,Comini G.Air-cooled condensing systems for home and industrial appliances[J].Applied Thermal Engineering,2005(10):1446-1458.
[3]周兰欣,白中华,李卫华.直接空冷机组空冷岛结构优化研究[J].汽轮机技术,2008,50(2):95-97.
[4]周兰欣,白中华,张淑霞,等.空冷平台外部流场的数值模拟[J].动力工程,2008,28(3):368-369.
[5]周兰欣,白中华,李卫华,等.600 MW机组空冷岛外部流场的数值模拟与结构优化[J].中国电机工程学报,2009,29(17):38-42.
[6]曾强,王智刚.空冷岛挡风墙最佳高度的数值模拟[J].热力发电,2011,40(10):21-24.
[7]周兰欣,曹智杰,弓学敏,等.直接空冷凝汽器加装曲面下挡风墙的数值模拟[J].电力建设,2011,32(9):1-5.
[8]陈梅倩,王玉叶,贾鹏程,等.挡风墙对直接空冷风机群流体动力学特性的影响[J].北京交通大学学报,2012,36(1):98-103.
[9]Bredell J R,Kroger D G,Thiart G D.Numerical investigation of fan performance in a forced draft air-cooled steam condenser[J].Applied Thermal Engineering,2006,26(8-9):846-852.
[10]Van Rooyen J A,Kr ger D G.Performance trends of an air-Cooled steam condenser under windy conditions[J].Journal of Engineering for Gas Turbines and Power,2008,130(2):023006.
[11]李剑宏.挡风墙挡风抑尘效果数值模拟研究[D].浙江:浙江大学航天航空学院,2007: 41-43.

[12]丁常富,丁振宇,侯乃明,等.直接空冷凝汽器加装防风网的数值模拟[J].动力工程,2009,29(10):956-959.