[1]Nizares C A C,Alvarado F L. Point of collapse and continuation methods for large AC/DC systems[J]. IEEE Transactions on Power Systems, 1993,8(1):1-8.
[2]Ajjarpu V. Identication of steady state voltage stability in power systems[J]. International Journal of Electric Power & Energy Systems, 1991(11):43-46.
[3]van Cutsem T. A method to compute reactive power margins with respect to voltage collapse[J]. IEEE Transactions on Power Systems, 1991,6(1):145-156.
[4]Lu J, Liu C W, Thorp J S. New methods for computing a saddle-node bifurcation point for voltage stability analysis[J]. IEEE Transactions on Power Systems, 1995,10(2):978-989.
[5]Parker C J, Morrison I F, Sutanto D. Application of an optimization method for determining the reactive margin from voltage collapse in reactive power planning[J]. IEEE Transactions on Power Systems, 1996,11(3):1473-1481.
[6]Haque M H. Use of V-I characteristic as a tool to assess the static voltage stability limit of a power system[J]. IEE Proceeding of Generation Transmission and Distribution,2004, 151(1):1-7.
[7]Haque M H. Novel method of assessing voltage stability of a power system using stability boundary in P_/Q plane [J]. Electric Power Systems Research, 2003,64(2): 35-40.
[8]袁骏, 段献忠,何仰赞.电力系统电压稳定灵敏度分析方法综述[J]. 电网技术,1997,9(21):21-25.
[9]Lf A, Smed T, Anderson G, et al. Fast calculation of a voltage stability index[J]. IEEE Transactions on Power systems, 1992, 7(1):54-64.
[10]Gao B, Morsion G K. Voltage stability evaluation using modal analysis[J].IEEE Transactions on Power systems, 1992,7(4):1529-1542.
[11]Feng Zhihong, Ajjarapu V, Maratukulam D J. A practical minimum load shedding strategy to minigate voltage collapse[J]. IEEE Transactions on Power Systems, 1998,13(4):1285-1291.
[12]Feng Zhihong, Ajjarapu V, Maratukulam D J. A comprehensive approach for preventive and corrective control to mitigate voltage collapse[J]. IEEE Transactions on Power Systems, 2000,15(2):791-797.
[13]Wang X, Ejebe G C, Tong J, et al. Preventive corrective control for voltage stability using direct interior point method[J]. IEEE Transactions on Power Systems,1998,13(3):878-883.
[14]Overbye T J. Computation of a practical method to restore power flower solvability[J]. IEEE Transactions on Power Systems, 1995,10(1):280-287.
[15]Overbye T J. A power flower measure for unsolvable cases[J]. IEEE Transactions on Power Systems, 1994,9(3):1359-1365.
[16]傅旭,王锡凡. 电力系统静态电压稳定性的在线监控(一):一种可在线应用的计及负荷静态特性的电压稳定指标[J]. 电力自动化设备,2005,25(8):23-26,31.
[17]傅旭,王锡凡. 电力系统静态电压稳定性的在线监控(二):一种在线确定负荷裕度的方法[J]. 电力自动化设备,2005,25(9):25-28.
[18]Ajjarapu V,Christy C.The continuation power flow: A toll for steady state voltage stability analysis[J].IEEE Transactions on Power Systems,1992,7(1):416-423.
[19]Capitanescu F, van Cutsem T. Preventive control of voltage security margins: a multicontingency sensitivity-based approach[J]. IEEE Transactions on Power Systems,2002,17(2):358-364.
[20]傅旭,王锡凡. 静态安全分析中的联动切负荷算法[J].中国电机工程学报,2006,26(9):82-86.
[21]Fu X, Wang X F. Unified preventive control approach considering voltage instability and thermaloverload[J]. IET Generation Transmission and Distribution,2007,1(6):864-871.
|