• CSCD核心库收录期刊
  • 中文核心期刊
  • 中国科技核心期刊

电力建设 ›› 2016, Vol. 37 ›› Issue (2): 112-117.doi: 10.3969/j.issn.1000-7229.2016.02.016

• 输配电技术 • 上一篇    下一篇

一种±800    kV直流换流阀技术改进方案及验证

郝长城1,王华锋1,杨万开2,王斌泽1,周亮3   

  1. 1.国网智能电网研究院,北京市 102209;2.中国电力科学研究院,北京市 100192;3.中电普瑞电力工程有限公司,北京市 102200
  • 出版日期:2016-02-01
  • 作者简介:郝长城(1983),男,硕士,工程师,主要研究方向为高压直流输电换流阀二次设备研发和工程应用; 王华锋(1978),男,硕士,高级工程师,研究方向为高压直流输电换流阀二次设备研发、电力电子技术等; 杨万开(1962),男,博士,高级工程师,主要研究方向为高压直流输电技术; 王斌泽(1988),男,硕士,工程师,主要研究方向为高压直流输电技术; 周亮(1984),男,工程师,研究方向为高压直流输电技术等。

Technology Improvement Scheme and Verification of ±800  kV DC Thyristor Valve

HAO Changcheng1, WANG Huafeng1, YANG Wankai2, WANG Binze1, ZHOU Liang3   

  1. 1. State Grid Smart Grid Research Institute, Beijing 102209, China;2. China Electric Power Research Institute, Beijing 100192, China;3. China-Epri Electric Engineering Co. Ltd., Beijing 102200, China
  • Online:2016-02-01

摘要:

哈密—郑州±800    kV直流输电工程哈密南换流站极Ⅱ低端换流阀技术改进工程是国内首次对国外品牌换流阀进行技术改进的工程。首先对原国外品牌换流阀的技术缺陷及相应技术改进方案进行了介绍。然后对工程现场分系统调试、站系统调试和系统调试等方案的设计和主要创新点进行梳理。最后对工程现场调式情况进行了介绍,结果显示,改进后的换流阀直流均压电阻运行温度显著降低,晶闸管状态检测机制更加完善。试验中未出现保护误动作或故障跳闸等错误,未出现换相失败等异常问题,改进后的换流阀性能参数满足工程设计要求。

关键词: 高压直流输电(HVDC), 换流阀, 型式试验, 工程调试

Abstract:

The technical improvement project of pole Ⅱ lower converter valve in ± 800 kV HVDC
 Southern  Hami south converter station is the first technical improvement project of certain foreign brand HVDC valve completed in China. This paper firstly introduces the technical defects and technical promotion programs of this foreign brand valve, and then discusses the designs and main innovation points of project commission programs of subsystem, station system and whole system. Site test analysis results show that the running temperature of DC grading resistor of improved thyristor valve is significantly reduced, and thyristor state detection mechanism is improved. There is no protection misoperation, fault trip or commutation failure in the test, and the performance parameters of improved thyristor valve meet the requirements of engineering design.

Key words: high voltage direct current (HVDC), thyristor valve, type test, project commissioning