火力发电厂筛碎设备的故障分析及改造

黄定贵

电力建设 ›› 2011, Vol. 32 ›› Issue (4) : 66-69.

PDF(535 KB)
PDF(535 KB)
电力建设 ›› 2011, Vol. 32 ›› Issue (4) : 66-69.
发电技术

火力发电厂筛碎设备的故障分析及改造

  • 黄定贵
作者信息 +

Fault Analysis and Renovation of Screening and Crushing Equipment of Coal-fired Power Plant

Author information +
文章历史 +

摘要

大唐华银株洲发电有限公司2×300 MW机组1、2 号滚轴筛、碎煤机在运行中经常发生积煤、堵煤、启动困难、电动机烧毁等故障,严重影响机组安全运行。对滚轴筛、碎煤机运行过程中出现的故障进行了原因分析,并提出了改进措施。筛碎设备改造后,运行状况良好,达到了设计参数,满足了生产要求。

Abstract

The No. 1 and 2 roller screen and coal crusher of the Datang Zhuzhou Huayin 2 × 300 MW units frequently have such faults during operation as coal deposition, coal block, difficult start-up and motor burnout, which have seriously affected the safe operation of unit. An analysis is conducted on the fault causes of the roller screen and coal crusher and some improvement measures are proposed. After renovation, the equipment works well and can meet the production requirements.

关键词

筛碎设备 / 滚轴筛 / 碎煤机 / 故障分析 / 改造

引用本文

导出引用
黄定贵. 火力发电厂筛碎设备的故障分析及改造[J]. 电力建设. 2011, 32(4): 66-69
Fault Analysis and Renovation of Screening and Crushing Equipment of Coal-fired Power Plant[J]. Electric Power Construction. 2011, 32(4): 66-69