采用大流量风吹法清理发电机短路事故污染物

李涟 罗新荣 杨夕云

电力建设 ›› 2012, Vol. 33 ›› Issue (4) : 107-110.

PDF(572 KB)
PDF(572 KB)
电力建设 ›› 2012, Vol. 33 ›› Issue (4) : 107-110.
施工技术

采用大流量风吹法清理发电机短路事故污染物

  • 李涟,罗新荣,杨夕云
作者信息 +

Duct Blowing Method for Pollution Cleaning in Short Circuit Accident by Large Flow Airs

Author information +
文章历史 +

摘要

为清理1 000 MW汽轮发电机定子短路事故所产生的污染物,采用了大流量风吹法对发电机定子铁芯背部、铁芯轴向风道、机座风道等部位进行吹扫,取得了良好的清理效果。详细介绍了定子冷却风道吹扫系统,论述了各吹扫阶段的注意事项,给出了吹扫效果的检验方法,对类似事故的处理具有一定的参考价值。

Abstract

This paper presented an efficient method for cleaning the pollution in stator short circuit accident of 1 000 MW turbine generator, which used large flow airs to blow stator core backside, core axial ducts, and generator base ducts. The blowing system of stator cooling ducts was introduced in details including the points for attention in every stage and the test method of blowing effect, which could provide reference for the similar accident treatment.

引用本文

导出引用
李涟 罗新荣 杨夕云. 采用大流量风吹法清理发电机短路事故污染物[J]. 电力建设. 2012, 33(4): 107-110
Duct Blowing Method for Pollution Cleaning in Short Circuit Accident by Large Flow Airs[J]. Electric Power Construction. 2012, 33(4): 107-110