PDF(1981 KB)
PDF(1981 KB)
PDF(1981 KB)
锅炉螺旋水冷壁T2钢内螺纹管渗漏事故分析
Analysis on Leakage Accident of T2 Internally Ribbed Tube of Spiral Water Wall in Boiler
采用宏观形貌检查、化学成分分析、力学性能测试、金相组织检验及扫描电镜分析等方法,对某660 MW超临界燃煤发电机组锅炉中部螺旋水冷壁T2钢内螺纹管的渗漏事故进行分析。结果表明,T2钢内螺纹管渗漏处的线性裂纹是在热轧成荒管时因工艺不当或管坯表面存在缺陷而形成的。建议制造厂加强对热轧荒管表面质量的检查;电厂对同批T2钢内螺纹管端头进行扩大检查,及时发现并消除类似缺陷。
The leakage accident of T2 internally ribbed tube in the middle part of spiral water wall in a 660 MW supercritical units was is analyzed by means of macro examination, chemical composition analysis, mechanical property tests, metallographic examination and scanning electron microscope. The results show that the leakage of T2 internally ribbed tube is due to the linear crack caused by improper hot rolling process of tube billet and the manufacturing defects of tube billet. So it should strengthen the surface quality inspection of hot rolled tube billet in manufactory; the inspection for the same batch of T2 internally ribbed tubes should be cairried out timely to eliminate similar defects in power plant.
螺旋水冷壁 / T2钢内螺纹管 / 裂缝 / 折叠 / 脱碳
spiral water wall / T2 internally ribbed tube / crack / enfoldment / decarbonrization
[1]ASME SA-213—2004 锅炉、过热器用无缝铁素体和换热器奥氏体合金钢管子[S].
[2]GB 5310—2008 高压锅炉用无缝钢管[S].
[3]彭孙鸿,邓尔康,刘彩玲,等. T2钢内螺纹管的研制[J]. 特殊钢,1999,20(6): 48-50.
[4]彭孙鸿,邓尔康,刘彩玲,等.SA-213T2钢内螺纹管的性能研究[J].钢管,2004,33(2): 19-21.
[5]王鲁义,陈其伟,朱国辉.12Cr1MoVG无缝钢管表面裂纹分析[J].安徽工业大学学报,2010,27(2): 135-139.
[6]周晓峰. 热轧无缝钢管内折缺陷分析[J]. 钢管,2009,38(5): 48-51.
[7]张惠萍,陈洪琪,卢玲玲,等. 连铸管坯质量对钢管内折缺陷的影响[J]. 钢管,2006,35(6): 27-30.
[8]田晓. 8号锅炉中部螺旋水冷壁管渗漏原因分析[R]. 西安:西安热工研究院有限公司,2012.
[9]成海涛. 无缝钢管缺陷与预防[M]. 成都:四川科学技术出版社,2009.
[10]何辅云,朱淮河. 无缝钢管折叠缺陷检测方法及装置[J]. 合肥工业大学学报:自然科学版,1999,22(3): 78-80.