基于AR法的输电塔结构三维空间风速时程模拟

汪江 陈喆 朱虹

电力建设 ›› 2011, Vol. 32 ›› Issue (10) : 54-57.

PDF(1993 KB)
PDF(1993 KB)
电力建设 ›› 2011, Vol. 32 ›› Issue (10) : 54-57.
输配电技术

基于AR法的输电塔结构三维空间风速时程模拟

  • 汪江1,陈喆2,朱虹2
作者信息 +

AR-based Structural Simulation of the Transmission Tower under 3D Wind Speed Time-histories

Author information +
文章历史 +

摘要

基于2E2-SZ2型220 kV输电塔结构的三维空间分析模型,考虑结构节点间的风速时程相关性,采用线性滤波法中的自回归(autoregressive,AR)模型,利用Matlab与Visual C++的混合编程技术,编制了高压输电塔结构的空间三维风速时程模拟程序。通过算例分析证明了其准确性和有效性,可为输电塔线的风振响应分析提供参考。

Abstract

In this paper, a 3D space analyzing model is built for the structure of 220 kV 2E2-SZ2 transmission tower. The wind speed time-histories relativity between the nodes of the structure is considered, the autoregressive (AR)model is adopted. Under the application of Matlab and Visual C++ mix-programming technique, a 3D wind speed time-histories simulation program of high-voltage transmission tower is developed. The calculation sample shows that the model is accuracy and effective. The model can be referenced in the future analysis of wind-vibration response for the transmission lines.

关键词

输电塔 / 风速时程 / 自回归(AR)模型 / 混合编程

Key words

输电塔 / 风速时程 / 自回归(AR)模型 / 混合编程

引用本文

导出引用
汪江 陈喆 朱虹. 基于AR法的输电塔结构三维空间风速时程模拟[J]. 电力建设. 2011, 32(10): 54-57
AR-based Structural Simulation of the Transmission Tower under 3D Wind Speed Time-histories[J]. Electric Power Construction. 2011, 32(10): 54-57