电瓷型高压电气设备的抗震试验及有限元分析

张军 齐立忠 李科文 陈大斌

电力建设 ›› 2011, Vol. 32 ›› Issue (7) : 6-10.

PDF(2819 KB)
PDF(2819 KB)
电力建设 ›› 2011, Vol. 32 ›› Issue (7) : 6-10.
重点理论研究

电瓷型高压电气设备的抗震试验及有限元分析

  • 张军1,齐立忠1,李科文2,陈大斌2
作者信息 +

Finite Element Analysis of Porcelain High-voltage Electrical Equipment

Author information +
文章历史 +

摘要

地震灾害调查资料显示,电瓷型高压电气设备在电网工程中破坏严重。结合震后电网受损情况的调研,对电瓷型高压电气设备进行振动台试验及有限元分析,评价目前电力设施抗震设计标准的适用性,在技术经济合理的前提下,提出了在工程建设中切实可行的抗震措施,使其能更好地指导工程设计。同时,提出了提高电瓷型高压电气设备抗震能力的建议。

Abstract

It is shown from the investigation of earthquake damages that the porcelain high-voltage electrical equipment in the power grids engineering is seriously damaged after the earthquake. Based on an investigation of the power grid damages in an earthquake, shaking table tests and finite element analysis (FEA) are conducted of the porcelain high-voltage electrical equipment in order to assess the applicability of the existing aseismatic design standards for electric power establishment. On the precondition of technical and economic rationality, some applicable aseismatic measures are proposed for better guiding engineering design. In addition, some suggestions are also proposed on improving the aseismatic capabilities for porcelain high-voltage electrical equipment.

关键词

电瓷型高压电气设备 / 抗震 / 振动试验 / 抗震设计标准 / 抗震措施

Key words

porcelain high-voltage electrical equipment / seismic resistance / shock test / aseismatic design standard / aseismatic measures

引用本文

导出引用
张军 齐立忠 李科文 陈大斌. 电瓷型高压电气设备的抗震试验及有限元分析[J]. 电力建设. 2011, 32(7): 6-10
Finite Element Analysis of Porcelain High-voltage Electrical Equipment[J]. Electric Power Construction. 2011, 32(7): 6-10

PDF(2819 KB)

Accesses

Citation

Detail

段落导航
相关文章
AI小编
你好!我是《电力建设》AI小编,有什么可以帮您的吗?

/