变电站操作绝缘地坪材料的绝缘性能

窦娟 吴小东

电力建设 ›› 2011, Vol. 32 ›› Issue (7) : 97-100.

PDF(387 KB)
PDF(387 KB)
电力建设 ›› 2011, Vol. 32 ›› Issue (7) : 97-100.
设备与材料

变电站操作绝缘地坪材料的绝缘性能

  • 窦娟,吴小东
作者信息 +

Study of Material Insulating Property of Operating Insulation Ground Floor in Substation

Author information +
文章历史 +

摘要

根据变电站中对接触电势校核的需要,对变电站内敷设的操作绝缘地坪的各种材质的绝缘性能进行了研究。结合试验结果和理论分析提出变电站内最适合采用的操作绝缘地坪的材质和厚度。研究结果表明,变电站内常规材质操作绝缘地坪的绝缘性能不都能满足变电站的安全运行的需要,建议采用复合材料的操作绝缘地坪。

Abstract

According to the demand of checking contact potential in substation, the material insulating properties of operating insulation ground floor are studied in this paper. The most suitable material and thickness of operating insulation ground floor is proposed by test and theoretical analysis. In addition, it is shown that not all the materials commonly used in substation meet the needs of safe operation in substations.

关键词

变电站 / 接触电势 / 绝缘地坪 / 绝缘性能 / 电阻率 / 安全运行

Key words

substation / contact potential / insulation ground floor / insulating property / resistivity / safe operation

引用本文

导出引用
窦娟 吴小东. 变电站操作绝缘地坪材料的绝缘性能[J]. 电力建设. 2011, 32(7): 97-100
Study of Material Insulating Property of Operating Insulation Ground Floor in Substation[J]. Electric Power Construction. 2011, 32(7): 97-100
中图分类号: TM8   

基金

中国电力工程顾问集团中南电力设计院科技项目