350 MW机组纯汽动给水泵启动的节能分析与应用

林隆

电力建设 ›› 2013, Vol. 34 ›› Issue (1) : 75-78.

PDF(512 KB)
PDF(512 KB)
电力建设 ›› 2013, Vol. 34 ›› Issue (1) : 75-78.
发电技术

350 MW机组纯汽动给水泵启动的节能分析与应用

  • 林隆

作者信息 +

Energy Saving Analysis and Application of Steam Pump Start-up in 350 MW Units

  • LIN Long
Author information +
文章历史 +

摘要

介绍了华能东方电厂二期工程3号机组配置1台100%锅炉最大连续蒸发量(boiler maximum continue rate,BMCR)容量汽动给水泵且无电动给水泵的启动特点,计算了机组启动过程全程使用汽动给水泵的节能效果,给出了纯汽动给水泵机组启停的实际情况,可为纯汽动给水泵启动机组设计提供参考。

Abstract

This paper introduces the start-up characteristics in Dongfang Power Plant Phase II No.3 unit, which is only equipped with steam feed pump for 100% boiler maximum continue rate (BMCR), but with no electric feed pump. The energy-saving effect by using steam pump in the whole process of units’ start-up is calculated, and the practical application of steam pump start-up is presented, which could provide references for the design of units started up only by steam feed pump.

关键词

汽动给水泵 / 纯汽动给水泵启动 / 节能

Key words

steam feed pump / only steam feed pump start-up / energy saving

引用本文

导出引用
林隆. 350 MW机组纯汽动给水泵启动的节能分析与应用[J]. 电力建设. 2013, 34(1): 75-78
LIN Long. Energy Saving Analysis and Application of Steam Pump Start-up in 350 MW Units[J]. Electric Power Construction. 2013, 34(1): 75-78

参考文献

[1]王舰,姜小军. 600  MW机组无电泵启动方式探讨[J]. 电力建设,2006,27(5):25-27.

[2]武云鹏. 1 000  MW机组纯汽泵启动的节能分析和给水系统改进方案[J]. 浙江电力,2011(1):15-19.

[3]胡洲.1 000  MW机组无电泵启动方式及特点[J]. 浙江电力,2010(9):43-46.

[4]文贤馗,申自明. 锅炉蒸汽吹管采用汽泵供水的工程实践[J]. 电力建设,2005,26(6):35-36,44.

[5]孙树哲. 600  MW机组无电泵启停方式研究与应用[J]. 科技信息,2010(35):1143-1137.

[6]姜广伟,武国良,杨洋. 300  MW机组汽动给水泵上水方式探讨[J]. 吉林电力,2005(5):15-17.

[7]叶明. 汽泵启停机组技术在350 MW机组上的应用[J]. 节能,2010(1):52-54.

[8]张洪波. 600  MW机组汽泵全过程给水分析[J]. 节能,2009(12):35-36,45.


PDF(512 KB)