PDF(1590 KB)
Common Quality Problems and Control of Factory Preparation for Four Major Pipes in Ultra Supercritical Thermal Power Units
Electric Power Construction ›› 2011, Vol. 32 ›› Issue (12) : 100-104.
PDF(1590 KB)
PDF(1590 KB)
Common Quality Problems and Control of Factory Preparation for Four Major Pipes in Ultra Supercritical Thermal Power Units
In this paper, common quality defects during factory preparation of the four major pipes in ultrasupercritical thermal power units are summarized and analyzed, such as surface quality, offdimension, hardness abnormal and metallographic structure abnormal, weld defects and so on. Then the corresponding quality control measures and suggestions are put forward, providing references for further improving the processing quality of the four major pipes.
/
| 〈 |
|
〉 |