The design of Datang International Linfen Cogeneration Power Plant in Shanxi is restricted by the construction sites. Therefore, an unique design plan is provided including the general arrangement, exhaust steam extraction of feedwater pump and turbine, dust extraction and machine layout of coal handling system, arrangement of water circulation pump house for auxiliary engine and et al, which ensures the design schedule and design quality, and is verified by the practical application.