Analysis and Modification of Drain in Block for LP Heater in 220 MW Units

Electric Power Construction ›› 2012, Vol. 33 ›› Issue (11) : 46-48.

PDF(509 KB)
PDF(509 KB)
Electric Power Construction ›› 2012, Vol. 33 ›› Issue (11) : 46-48.

Analysis and Modification of Drain in Block for LP Heater in 220 MW Units

Author information +
History +

Abstract

This paper analyzed the reason of drain in block in No.3 low pressure (LP) heater in 220 MW units during the startup and debugging stage. Based on the real-time data, the original design parameters and the site situation, the drainage systems in No.2, No.3 LP heaters were modified, and the cooling water of slag cooler was adjusted, in order to solve the drain in block in No.3 LP heater. Finally, this paper suggested the solution for the influence of cooling waters backwater temperature in slag cooler on the No.3 LP heaters drain

Cite this article

Download Citations
Analysis and Modification of Drain in Block for LP Heater in 220 MW Units[J]. Electric Power Construction. 2012, 33(11): 46-48
PDF(509 KB)

Accesses

Citation

Detail

Sections
Recommended

/