PDF(2138 KB)
Fault Analysis of Transmission Tower Main Material in Low Temperature
Electric Power Construction ›› 2012, Vol. 33 ›› Issue (3) : 86-88.
PDF(2138 KB)
PDF(2138 KB)
Fault Analysis of Transmission Tower Main Material in Low Temperature
Fracture of primary materials in transmission tower is analyzed, main conclusions of material failure are drawn and suggestions for improvement is put forward by analyzing bearing capacity, chemical properties, low-temperature tensile properties, fracture part of main material and microstructure of the main fracture material. The results show that main reason for material failure is low-temperature brittle fracture which is mainly caused by cracks in the process of punching.
/
| 〈 |
|
〉 |