Crack Analysis of T23 Steel Tube Welded Joints for 1 000 MW Ultra Supercritical Tower-type Boiler

Electric Power Construction ›› 2012, Vol. 33 ›› Issue (4) : 90-92.

PDF(3742 KB)
PDF(3742 KB)
Electric Power Construction ›› 2012, Vol. 33 ›› Issue (4) : 90-92.

Crack Analysis of T23 Steel Tube Welded Joints for 1 000 MW Ultra Supercritical Tower-type Boiler

Author information +
History +

Abstract

The macro-inspection and microstructure analysis of cracks for welded joints were investigated, according to the leakage of T23 Steel tube welded joints in a 1 000 MW ultra supercritical tower-type boiler. The result shows that the water-wall tube weld cracks are caused by residual stress and structural binding stress of welded joints.

Cite this article

Download Citations
Crack Analysis of T23 Steel Tube Welded Joints for 1 000 MW Ultra Supercritical Tower-type Boiler[J]. Electric Power Construction. 2012, 33(4): 90-92