Cause Analysis of Ammonia Escape in SCR Flue Gas Denitrification Process for 600 MW Units

Electric Power Construction ›› 2012, Vol. 33 ›› Issue (6) : 67-70.

PDF(714 KB)
PDF(714 KB)
Electric Power Construction ›› 2012, Vol. 33 ›› Issue (6) : 67-70.

Cause Analysis of Ammonia Escape in SCR Flue Gas Denitrification Process for 600 MW Units

Author information +
History +

Abstract

This paper pointed out that the basic reason of air preheater’s corrosion and blocking in the selective catalytic reduction (SCR) flue gas denitrification process was ammonia escape. The influence of flow field distribution, automatic regulation for the ammonia spraying and flue gas analysis instruments on the ammonia escape were investigated, in order to suggest the method of reducing ammonia escape. The result shows that the grid nozzle for ammonia spraying should be improved.

Key words

flue gas denitrification / air preheater / ammonia escape / NH4HSO4

Cite this article

Download Citations
Cause Analysis of Ammonia Escape in SCR Flue Gas Denitrification Process for 600 MW Units[J]. Electric Power Construction. 2012, 33(6): 67-70
PDF(714 KB)

Accesses

Citation

Detail

Sections
Recommended

/