PDF(752 KB)
Vibration Analysis for Direct Air-Cooling Fan System in Power Plant
Electric Power Construction ›› 2012, Vol. 33 ›› Issue (7) : 43-45.
PDF(752 KB)
PDF(752 KB)
Vibration Analysis for Direct Air-Cooling Fan System in Power Plant
According to the excessive vibration of the air-cooling fan bridge in a power plant, this paper analyzed the main reasons of the fan bridge’s vibration and put forward different improvement schemes, whose field tests had been carried out. The test results show that the fan bridge vibration can be significantly reduced by changing the natural frequency of the fan bridge and the fan blade numbers. The research results can provide references for the engineering design and the vibration analysis of the air-cooling fan bridge.
/
| 〈 |
|
〉 |