This paper introduces the start-up characteristics in Dongfang Power Plant Phase II No.3 unit, which is only equipped with steam feed pump for 100% boiler maximum continue rate (BMCR), but with no electric feed pump. The energy-saving effect by using steam pump in the whole process of units’ start-up is calculated, and the practical application of steam pump start-up is presented, which could provide references for the design of units started up only by steam feed pump.
steam feed pump / only steam feed pump start-up / energy saving
[1]王舰,姜小军. 600 MW机组无电泵启动方式探讨[J]. 电力建设,2006,27(5):25-27.
[2]武云鹏. 1 000 MW机组纯汽泵启动的节能分析和给水系统改进方案[J]. 浙江电力,2011(1):15-19.
[3]胡洲.1 000 MW机组无电泵启动方式及特点[J]. 浙江电力,2010(9):43-46.
[4]文贤馗,申自明. 锅炉蒸汽吹管采用汽泵供水的工程实践[J]. 电力建设,2005,26(6):35-36,44.
[5]孙树哲. 600 MW机组无电泵启停方式研究与应用[J]. 科技信息,2010(35):1143-1137.
[6]姜广伟,武国良,杨洋. 300 MW机组汽动给水泵上水方式探讨[J]. 吉林电力,2005(5):15-17.
[7]叶明. 汽泵启停机组技术在350 MW机组上的应用[J]. 节能,2010(1):52-54.
[8]张洪波. 600 MW机组汽泵全过程给水分析[J]. 节能,2009(12):35-36,45.
/
| 〈 |
|
〉 |