Abstract

The converter valve is the core equipment in DC power transmission system, and the temperature monitoring of valve hall equipment is of great significance to guarantee the safe operation of converter valve. Based on ± 200 kV multiterminal-flexible DC transmission project in Zhoushan, the structure of valve hall in converter station and the characteristics of valve hall equipment are described, and three kinds of temperature measurement schemes for valve hall equipment: infrared, optical and wireless are proposed. Finally, through a comparison of technology and safety, the infrared temperature measurement scheme is presented that could satisfy the monitoring requirements without affecting the structure of valve body. It is suggested that the temperature measurement of flexible DC valve hall equipment should apply infrared method.

Key words

flexible DC / converter station / valve hall / valve module / infrared temperature measurement

Cite this article

Download Citations
LI Guoyao, LIU Sheng, XU Feng, ZHOU Zhichao. Temperature Monitoring of Valve Hall Equipment in Flexible DC Converter Station[J]. Electric Power Construction. 2013, 34(6): 92-97

References

 [1]汤广福.基于电压源换流器的高压直流输电技术[M].北京市:中国电力出版社,2010.


[2]国家电网公司.Q/GDW 381.9—2011 国家电网公司输变电工程施工图设计内容深度规定 第9部分:高压直流换流站[S].北京:中国电力出版社,2011.

[3]中国电力企业联合会.DL /T 5223—2005 高压直流换流站设计技术规定[S].北京:中国电力出版社,2005.

[4]孙昕,刘泽洪,高理迎,等.±800 kV特高压直流工程创新实践[J].中国电机工程学报,2009,29(22):35-45.

[5]徐斌,林光龙,李家干.浅谈换流站高端阀厅主设备安装工艺与质量控制[J].南方电网技术,2008,2(04):80-82.

[6]张凌,杨金根,曾静.特高压阀厅电气设计研究[J].电力建设,2007,28(5):12-16.

[7]杨定俊,陈楠,王坚英,等.换流阀高层光纤敷设方案设计及优化[J].上海电力,2011(2):129-131.

[8]赵炳成,沈立新,丁周松. 基于ZigBee技术的高压开关柜温度在线监测系统[J].浙江电力,2012(2):16-18.

[9]邵勇,琚军.红外诊断技术在继电保护工作中的应用[J].浙江电力,2012(4):22-24.

[10]林培根.变电运行过程中的红外测温及其应用[J].技术与市场,2012,19(6):205-206.

[11]中国电力企业联合会.DL/T 664—2008 带电设备红外诊断应用规范[S].北京:中国电力出版社,2008.