Electric Power Construction ›› 2013, Vol. 34 ›› Issue (3) : 12-16.
PDF(498 KB)
PDF(498 KB)
Galloping of conductor with thin ice accretions is a common but unexplained phenomenon. Wind tunnel tests are needed to study the aerodynamic characteristics of conductors with thin ice accretions. Based on the galloping investigation of real transmission lines with ice, three conductor models with different ice thickness are designed and tested in the wind tunnel. The average aerodynamics of quasi-oval shape iced conductor models in two different flow fields are measured by using six-component high-frequency balance. Through the comparison and analysis of average aerodynamic coefficients, Den Hartog coefficient is found not suitable for the analysis on thin ice wire. On the basis of qualitative explanation of Den Hartog to galloping, two necessary conditions of galloping are proposed. Through the analysis of test results, the wind attack angle has been acquired when the conductor gallops with thin ice accretions.
thin ice accretions / conductor galloping / wind tunnel test / aerodynamic force / galloping instability
[1]湖南省电力试验研究院.12.27长沙、湘潭地区线路跳闸情况分析报告[R].长沙:湖南省电力试验研究院,2009.
[2]郭应龙,李国兴,尤传永.输电线路舞动[M].北京:中国电力出版社,2003.
[3]Den Hartog J P. Transmission Line vibration due to sleet [J].Transactions AIEE, 1932, 51(4):1074-1086.
[4]Nigol O, Buchan P G. Conductor galloping-part 1: Denhartog mechanism [J]. IEEE Transactions on Power Apparatus and Systems,1981, PAS-100(2): 699-707.
[5]Nigol O, Buchan P G. Conductor galloping-part 2: Torsional mechanism [J]. IEEE Transactions on Power Apparatus and Systems, 1981, PAS-100(2): 708-720.
[6]Richardson A S. Predicting galloping amplitudes[J].ASCE Journal of Engineering Mechanics, 1988.114(4): 716-723.
[7]RichardsonA S. Predicting galloping amplitudes: II[J]. Journal of Engineering Mechanics, 1988, 114(11): 1945-1952.
[8]Yu P, Popplewell N, Shah A H. Instability trends of inertrially coupled galloping part I: Periodic vibrations [J]. Journal of Sound and Vibration.1995,183(4): 663-678.
[9]Yu P, Desai Y M, Shah A H, et al. Three-degree-of-freedom model for galloping part I: Formulation[J].ASCE Journal of Engineering Mechanics, 1993, 119(12): 2404-2425.
[10]何锃,赵高煜.安装失谐摆的大跨越分裂导线自由振动计算[J]. 中国电机工程学报,2003, 23(2): 63-66.
[11]何锃,赵高煜. 分裂导线扭转舞动分析的动力学模型[J].工程力学,2001,18(2): 126-134.
[12]蒋兴良,张丽华.导线覆冰碰冻率及最大覆冰直径分析[J]. 中国电机工程学报,1999, 19(9): 10-13.
[13]孙才新,蒋兴良,熊启新,等.导线覆冰及其干湿增长临界条件分析[J].中国电机工程学报, 2003, 23(3): 141-145.
[14]顾明,马文勇,全涌,等.两种典型覆冰导线气动力特性及稳定性分析[J]. 同济大学学报:自然科学版, 2009, 37(10): 1328-1332.
[15]顾明,马文勇,全涌,等.准椭圆形覆冰导线气动力特性实验研究[J].同济大学学报:自然科学版,2010,38(10): 1409-1413.
[16]GB 50009—2001 建筑结构荷载规范[S].北京:中国建筑工业出版社,2002.
PDF(498 KB)
/
| 〈 |
|
〉 |