Hierarchical Protection & Control System for New Generation Smart Substation

SONG Xuankun, LI Yingchao, LI Jun, XIAO Zhihong, LIU Ying,YAN Peili

Electric Power Construction ›› 2013, Vol. 34 ›› Issue (7) : 24-29.

PDF(1338 KB)
PDF(1338 KB)
Electric Power Construction ›› 2013, Vol. 34 ›› Issue (7) : 24-29.

Hierarchical Protection & Control System for New Generation Smart Substation

  • SONG Xuankun1, LI Yingchao2, LI Jun1, XIAO Zhihong1, LIU Ying1,YAN Peili1
Author information +
History +

Abstract

A strong smart grid requires relay protection not only to improve its performance, but enhance the optimization and coordination with stability control system as well. A new concept of hierarchical protection & control system oriented to regional grid security and stability was proposed. On the basis of conventional protection configuration, the substation-area protection & control unit and wide-area protection & control unit based on information sharing were set up. Then, the framework and function deployment of hierarchical protection & control system, as well as its application examples were introduced. Through the comparison with the existed protection scheme and wide-area protection scheme, its performance was also analyzed. The results have shown that the proposed hierarchical protection & control system can be promoted and applied in smart substation construction as application scheme.

Key words

smart grid / smart substation / hierarchical protect & / control / substation-area protection / wide-area protection & / control

Cite this article

Download Citations
SONG Xuankun, LI Yingchao, LI Jun, XIAO Zhihong, LIU Ying,YAN Peili. Hierarchical Protection & Control System for New Generation Smart Substation[J]. Electric Power Construction. 2013, 34(7): 24-29

References

 


[1]张保会. 加强继电保护与紧急控制系统的研究提高互联电网安全防御能力 [J]. 中国电机工程学报, 2004, 24(7): 5-10.

[2]张保会. 电网继电保护与实时安全性控制面临的问题与需要开展的研究 [J]. 电力自动化设备, 2004, 24(7): 1-6.

[3]周孝信, 郑健超, 沈国荣, 等. 从美加东北部电网大面积停电事故中吸取教训 [J]. 电网技术, 2003, 27(9): 1.

[4]丛伟, 潘贞存, 丁磊, 等. 满足“三道防线”要求的广域保护系统及其在电力系统中的应用 [J]. 电网技术, 2004, 28(18): 29-33.

[5]朱永利, 宋少群. 基于广域网和多智能体的自适应协调保护系统的研究 [J]. 中国电机工程学报, 2006, 26(16): 15-20.

[6]童晓阳, 王晓茹, 汤俊. 电网广域后备保护代理的结构和工作机制研究 [J]. 中国电机工程学报, 2008, 28(13): 91-98.

[7]赵曼勇, 周红阳, 陈朝晖, 等. 广域一体化继电保护系统方案 [J]. 南方电网技术, 2009, 3(6): 9-12.

[8]尹项根, 汪旸, 张哲. 适应智能电网的有限广域继电保护分区与跳闸策略 [J]. 中国电机工程学报, 2010, 30(7): 1-7.

[9]赵曼勇, 周红阳, 陈朝晖, 等. 基于IEC 61850标准的广域一体化保护方案 [J]. 电力系统自动化, 2010, 34(6): 58-60.

[10]马静, 李金晖, 李金龙, 等. 快速适应电网结构变化的广域后备保护新方法 [J]. 电网技术, 2011, 35(7): 214-21.

[11]吴国旸, 王庆平, 李刚. 基于数字化变电站的集中式保护研究 [J]. 电力系统保护与控制, 2009, 37(10): 15-18.

[12]高东学, 智全中, 朱丽均, 等. 智能变电站保护配置方案研究 [J]. 电力系统保护与控制, 2012, 40(1): 68-71.

[13]李锋, 谢俊, 兰金波, 等. 智能变电站继电保护配置的展望和探讨 [J]. 电力自动化设备, 2012, 32(2): 122-126.

[14]戴志辉. 继电保护可靠性及其风险评估研究[D].北京:华北电力大学, 2012.